Yes. In addition to the applications we may be more accustomed to, such as collectors, elements supporting discontinuous systems, and transfer elements, the foundation elements below cantilevered columns systems require the overstrength factor to be applied. ASCE 7-22 § 12.2.5.2 permits the use of this system in seismic design categories B through F with two key limitations:

  1. Limiting the strength-level axial load on an individual cantilevered column to 15% of its axial design strength.
  2. Requiring the foundation, and any other element providing resistance to overturning, to be designed using the seismic load effect including overstrength per ASCE 7-22 § 12.4.3.

The special attention toward this system is codified to provide an adequate margin against collapse considering the uniqueness of this system. A lack of redundancy warrants the overstrength factor being applied to provide accountability for the localization of inelastic behavior at the base of the columns. Without it, such an R-value listed in Table 12.2-1 would not be an appropriate assumption of the response of the system.